| MOQ: | 10 |
| Price: | USD 800~2000/unit |
| Standard Packaging: | Steel Bracket |
| Delivery Period: | 30 days |
| Payment Method: | T/T |
| Supply Capacity: | 1000EU/M |
Available in 5KW, 8KW, 10KW, 13KW and other power units to meet specific customer requirements including integrated air conditioning + battery, battery + air conditioning + motor cooling, and comprehensive heat management with heat recovery functionality.
Note: Unit selection is based on battery capacity and specific customer integrated thermal management requirements. Suitable for various vehicle types including light trucks, buses, heavy trucks, construction machinery, and mining vehicles.
| Parameter | NBSLJZ-03-01 |
|---|---|
| Rated cooling capacity (kW) | 3.5 |
| Low-voltage power demand | 450W |
| High voltage power supply | DC400V-DC750V |
| Low voltage power supply | DC24V(18V-32V) |
| Built in water pump | >20L/min @110 KPa |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | R134a |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 530(L)*446(W)*365(H) |
| Unit fixed point | Φ12 holes *4 |
| Joint | Inlet and outlet water pipeΦ25 |
| Connector | Configurable per customer requirements |
| Low voltage power | 24V 450W |
| Parameter | NBSLJZ-05-01 |
|---|---|
| Rated cooling capacity (kW) | 5 |
| Heating capacity | 6-14kW (Optional) |
| High voltage power supply | Rated voltage 320VDC (220~450 VDC) |
| Low voltage power supply | DC24V(18V-32V) |
| Built in water pump | 11m&1800l/h |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | R134a |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 635(L)*530(W)*380(H) |
| Unit fixed point | 569mm*369mm Φ12holes *4 |
| Joint | Inlet and outlet water pipeΦ25 |
| Connector | Configurable per customer requirements |
| Low voltage power | 24V 600W |
| Parameter | NBSLJZ-08-01 |
|---|---|
| Rated cooling capacity (kW) | 8 |
| Low-voltage power demand | 600W |
| High voltage power supply | DC400V-DC750 |
| Built in water pump | 20m&2000l/h |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | 134a/R407C |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 820(L)*575(W)*285(H) |
| Unit fixed point | 495mm*320mm Φ12holes *6 |
| Joint | Inlet and outlet water pipeΦ25 (Reserved overflow pipeΦ8) |
| Connector | Configurable per customer requirements |
| Electronic control | Four in one/Three in one integrated |
| Parameter | NBSLJZ-10-01 |
|---|---|
| Rated cooling capacity (kW) | 10 |
| Heating capacity | 24KW (Optional) |
| High voltage power supply | 640VDC (400~750 VDC) |
| Built in water pump | 17.5m&2880l/h |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | 134a |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 960(L)*603(W)*291(H) |
| Unit fixed point | 521mm*320mm Φ12holes *6 |
| Joint | Inlet and outlet water pipeΦ25 (Reserved overflow pipeΦ8) |
| Connector | Configurable per customer requirements |
| Electronic control | Four in one/Three in one integrated |
| Parameter | NBSLJZ-13-01 |
|---|---|
| Rated cooling capacity (kW) | 12 |
| Heating capacity (kW) | Optional 24KW-30KW |
| High voltage power supply | DC400V-DC750V |
| Low voltage power supply range | DC 18~32V |
| Energy efficiency ratio | 2.0 |
| Protection level | IPX7 |
| Refrigerant | 134a/R407C |
| Type of secondary refrigerant | 50%/50% Ethylene glycol aqueous solution |
| Dimensions | L1370*W1030*H285 mm |
| Unit fixed point | Φ12holes *8 |
| Joint | Inlet and outlet water pipeΦ25 |
| Connector | Configurable per customer requirements |
| Electronic control | Four in one/Three in one integrated |
|
|
| MOQ: | 10 |
| Price: | USD 800~2000/unit |
| Standard Packaging: | Steel Bracket |
| Delivery Period: | 30 days |
| Payment Method: | T/T |
| Supply Capacity: | 1000EU/M |
Available in 5KW, 8KW, 10KW, 13KW and other power units to meet specific customer requirements including integrated air conditioning + battery, battery + air conditioning + motor cooling, and comprehensive heat management with heat recovery functionality.
Note: Unit selection is based on battery capacity and specific customer integrated thermal management requirements. Suitable for various vehicle types including light trucks, buses, heavy trucks, construction machinery, and mining vehicles.
| Parameter | NBSLJZ-03-01 |
|---|---|
| Rated cooling capacity (kW) | 3.5 |
| Low-voltage power demand | 450W |
| High voltage power supply | DC400V-DC750V |
| Low voltage power supply | DC24V(18V-32V) |
| Built in water pump | >20L/min @110 KPa |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | R134a |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 530(L)*446(W)*365(H) |
| Unit fixed point | Φ12 holes *4 |
| Joint | Inlet and outlet water pipeΦ25 |
| Connector | Configurable per customer requirements |
| Low voltage power | 24V 450W |
| Parameter | NBSLJZ-05-01 |
|---|---|
| Rated cooling capacity (kW) | 5 |
| Heating capacity | 6-14kW (Optional) |
| High voltage power supply | Rated voltage 320VDC (220~450 VDC) |
| Low voltage power supply | DC24V(18V-32V) |
| Built in water pump | 11m&1800l/h |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | R134a |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 635(L)*530(W)*380(H) |
| Unit fixed point | 569mm*369mm Φ12holes *4 |
| Joint | Inlet and outlet water pipeΦ25 |
| Connector | Configurable per customer requirements |
| Low voltage power | 24V 600W |
| Parameter | NBSLJZ-08-01 |
|---|---|
| Rated cooling capacity (kW) | 8 |
| Low-voltage power demand | 600W |
| High voltage power supply | DC400V-DC750 |
| Built in water pump | 20m&2000l/h |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | 134a/R407C |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 820(L)*575(W)*285(H) |
| Unit fixed point | 495mm*320mm Φ12holes *6 |
| Joint | Inlet and outlet water pipeΦ25 (Reserved overflow pipeΦ8) |
| Connector | Configurable per customer requirements |
| Electronic control | Four in one/Three in one integrated |
| Parameter | NBSLJZ-10-01 |
|---|---|
| Rated cooling capacity (kW) | 10 |
| Heating capacity | 24KW (Optional) |
| High voltage power supply | 640VDC (400~750 VDC) |
| Built in water pump | 17.5m&2880l/h |
| Control power supply | DC24V battery provides on/off signal |
| Protection level | IPX7 |
| Refrigerant | 134a |
| Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
| Dimensions | 960(L)*603(W)*291(H) |
| Unit fixed point | 521mm*320mm Φ12holes *6 |
| Joint | Inlet and outlet water pipeΦ25 (Reserved overflow pipeΦ8) |
| Connector | Configurable per customer requirements |
| Electronic control | Four in one/Three in one integrated |
| Parameter | NBSLJZ-13-01 |
|---|---|
| Rated cooling capacity (kW) | 12 |
| Heating capacity (kW) | Optional 24KW-30KW |
| High voltage power supply | DC400V-DC750V |
| Low voltage power supply range | DC 18~32V |
| Energy efficiency ratio | 2.0 |
| Protection level | IPX7 |
| Refrigerant | 134a/R407C |
| Type of secondary refrigerant | 50%/50% Ethylene glycol aqueous solution |
| Dimensions | L1370*W1030*H285 mm |
| Unit fixed point | Φ12holes *8 |
| Joint | Inlet and outlet water pipeΦ25 |
| Connector | Configurable per customer requirements |
| Electronic control | Four in one/Three in one integrated |